ELECTRICIAN'S MATE (NUCLEAR) - EM (NUC)


Note: Below are listed responsibilities for grades E-4 (3) and E-7 (c) for this job. Paygrades E-1 through E-3 assist in these tasks


EM3 (NUC)

A. ELECTRICAL INSTALLATION
A4.001 RIG AND TEST SHORE POWER CABLES
A4.002 UNRIG SHORE POWER CABLES
A4.003 RIG AND TEST CASUALTY POWER CABLES (SURFACE SHIPS ONLY)
A4.004 UNRIG CASUALTY POWER CABLES (SURFACE SHIPS ONLY)
A4.005 PERFORM ELECTRICAL SAFETY CHECKS

B. POWER DISTRIBUTION
B4.001 MANUALLY SHIFT AN ABT FROM NORMAL TO ALTERNATE POWER
B4.002 PERFORM OPERATION TESTS AND MAINTENANCE ON AN ABT
B4.003 SHIFT AN MBT FROM NORMAL TO ALTERNATE POWER
B4.004 CLEAN AND INSPECT AN ELECTRICAL DISTRIBUTION
SWITCHBOARD
B4.005 PERFROM OPERATION TESTS ON THE PRESSURE AND PHOTO
SENSORS ON THE ARC FAULT DETECTION SYSTEM (SUBMARINES
ONLY)
B4.006 CLEAN AND INSPECT AN ACB CIRCUIT BREAKER
B4.007 CLEAN AND INSPECT AN AQB CIRCUIT BREAKER
B4.008 CLEAN AND INSPECT AN AQB-LF CIRCUIT BREAKER
B4.009 REPLACE A CIRCUIT BREAKER
B4.010 PERFORM GROUND ISOLATION FROM THE EPCP AND THE SPACES

C. MOTORS AND GENERATORS
C4.001 REPLACE AND SEAT BRUSHES IN A MOTOR/GENERATOR
C4.002 CLEAN AND INSPECT A MOTOR
C4.003 CLEAN AND INSPECT A GENERATOR

D. LIGHTING SYSTEMS
D4.001 CLEAN AND INSPECT LIGHTING SYSTEM COMPONENTS
D4.002 REPLACE A BALLAST IN A LIGHTING ASSEMBLY

E. PROPULSION CONTROL
E4.001 SHIFT THROTTLE CONTROL FROM REMOTE TO LOCAL

F. ELECTRICAL EQUIPMENT
F4.001 REPLACE THE MAIN LINE CONTACTS IN A MOTOR CONTROLLER
F4.002 PERFORM TIMING CHECKS AND ADJUSTMENTS ON A DC MOTOR
CONTROLLER (SUBMARINES ONLY)
F4.003 CLEAN AND INSPECT THE SSMG STARTER/REGULATOR
(SUBMARINES ONLY)
F4.004 CLEAN AND INSPECT AN ELECTROSTATIC PRECIPITATOR
F4.005 CLEAN AND INSPECT A VENT FOG PRECIPITATOR
F4.006 CLEAN AND INSPECT A SALINITY CELL

F4.007 ADJUST A SALINITY CHANNEL MODULE ALARM SETPOINT
F4.008 ADJUST A TEMPERATURE MONITORING MODULE ALARM SETPOINT
F4.009 SHOW PROFICIENCY IN THE USE OF A FLUKE
F4.010 SHOW PROFICIENCY IN THE USE OF A MEGGER
F4.011 SHOW PROFICIENCY IN THE USE OF AN OSCILLOSCOPE

G. TECHNICAL ADMINISTRATION
_G4.001 SHOW PROFICIENCY IN READING ELECTRICAL
SCHEMATICS/DIAGRAMS

H. BASIC ENGINEERING
H4.001 OPERATE THE MAIN COOLANT PUMP/REACTOR COOLANT PUMP
MONITOR
H4.002 PERFORM A TURBIDITY
H4.003 READ AND ZERO A SELF-INDICATING POCKET DOSIMETER
H4.004 CONDUCT ROUTINE CHECKS OF RADIACS
H4.005 PERFORM RADIATION, SURFACE CONTAMINATION, AND AIR
PARTICULATE SURVEYS
H4.006 SETUP AND OPERATE A COUNTING STATION

EM2 (NUC)

B. POWER DISTRIBUTION
B5.001 OPEN CIRCUIT THE MAIN STORAGE BATTERY (SUBMARINES ONLY)
B5.002 PERFORM AN INSPECTION OF THE MAIN STORAGE BATTERY
(SUBMARINES ONLY)
B5.003 PERFORM A TEST DISCHARGE FROM THE EPCP AND THE ICV
PANEL (SUBMARINES ONLY)
B5.004 PARTICIPATE IN SWITCHBOARD TESTING
B5.005 PARTICIPATE IN REACTOR ENGINEERED SAFEGUARDS SYSTEM
ELECTRICAL TESTS (SURFACE ONLY)

C. MOTORS AND GENERATORS
C5.001 MEASURE THE TOTAL INDICATOR RUNOUT OF A SLIP/COLLECTOR
RING
C5.002 PERFORM MOTOR-GENERATOR OVERSPEED TRIP CHECKS FROM THE
EPCP AND LOCALLY (SUBMARINES ONLY)

E. PROPULSION CONTROL
E5.001 PARTICIPATE IN THE INSPECTION AND LUBRICATION OF
PROPULSION CONTROL CONSOLE COMPONENTS

F. ELECTRICAL EQUIPMENT
F5.001 PERFORM SUBMARINE HULL SOUND CUTS (SUBMARINES ONLY)
F5.002 PERFORM MACHINERY SOUND CUTS
F5.003 SHOW PROFICIENCY IN SOLDERING ELECTRICAL CONNECTIONS

G. TECHNICAL ADMINISTRATION
G5.001 UPDATE MATERIAL HISTORY
G5.002 UPDATE THE BATTERY RECORD BOOK (SUBMARINES ONLY)
G5.003 DRAFT A COMPONENT FAILURE REPORT

EM1 (NUC)

A. ELECTRICAL INSTALLATION
A6.001 COORDINATE THE INSTALLATION OF AN ELECTRICAL
ENGINEERING FIELD CHANGE

B. POWER DISTRIBUTION
B6.001 COORDINATE SWITCHBOARD TESTING
B6.002 COORDINATE REACTOR ENGINEERED SAFEGUARDS SYSTEM
ELECTRICAL TESTS (SURFACE ONLY)
F. ELECTRICAL EQUIPMENT
F6.001 ANALYZE AND INTERPRET SOUND CUTS
F6.002 ANALYZE AND EVALUATE THERMAL IMAGING DATA

G. TECHNICAL ADMINISTRATION
G6.001 DRAFT REACTOR PLANT WORK PACKAGE
G6.002 DRAFT A LIAISON ACTION REQUEST
G6.003 PREPARE AN RPPMS QUARTERLY AND WEEKLY SCHEDULE

H. BASIC ENGINEERING
H6.001 CALCULATE STARUP CRITICAL POSITION (ECP)
H6.002 CALCULATE MAN-REM REQUIREMENTS FOR WORK IN RADIOLOGICAL
AREAS
H6.003 ASSESS PERSONNEL EXPOSURE VERSUS MAN-REM BUDGET
H6.004 EVALUATE COMPARTMENT ISOLATION REQUIREMENTS
H6.005 COORDINATE ELECTRIC PLANT STARTUP

EMC (NUC)

G. TECHNICAL ADMINISTRATION
G7.001 CONDUCT A RADIOLOGICAL CONTROLS SURVEILLANCE
G7.002 PERFORM A REACTOR CONTROLS AUDIT AND SURVEILLANCE
G7.003 CONDUCT A QA AUDIT AND SURVEILLANCE

D. QUALITY ASSURANCE (QA)
D7.001 PERFORM A QA AUDIT AND SURVEILLANCE

H. BASIC ENGINEERING
H7.001 SUPERVISE REACTOR STARTUP
H7.002 SUPERVISE REACTOR SHUTDOWN
H7.003 SUPERVISE AN ENGINE ROOM STARTUP
H7.004 SUPERVISE AN ENGINE ROOM SHUTDOWN
H7.005 ANALYZE PRIMARY CHEMISTRY RESULTS
H7.006 ANALYZE SECONDARY CHEMISTRY RESULTS
H7.007 SUPERVISE PROPULSION PLANT CASUALTY RESPONSE
H7.008 SUPERVISE A SHUTDOWN WATCH SECTION
H7.009 SUPERVISE A STEAMING WATCH SECTION


Index

            
Explore US Military
About.com Special Features

The Best Job Search Websites

A list of the best places on the web to find job listings and job search help. More >

How to Write a Cover Letter

Looking for a new job? Use these tips and put your best foot forward. More >

  1. Home
  2. Careers
  3. US Military

©2010 About.com, a part of The New York Times Company.

All rights reserved.